Super Air Nozzle Cluster

EXAIR's Super Air Nozzle clusters are an array of Model 1100, 1/4 NPT Super Air Nozzles on a round manifold which provide
Only %1 left

View More
EXAIR's Super Air Nozzle clusters are an array of Model 1100, 1/4 NPT Super Air Nozzles on a round manifold which provide force values that are similar to our largest nozzles but at lower decibel levels. These nozzles can be used in areas where low noise levels are the first consideration. All aluminum construction from 3/8 FNPT through 1 FNPT. Force values from 3.2 lbs (1.45 kg) through 9.8 lbs (4.45 kg)

Applications

  • Part cleaning
  • Chip removal
  • Liquid blowoff
  • Part cooling
  • Material conveying
  • Part ejection
  • Fiber conveying
  • Air assist

Advantages

  • Reduced compressed air cost
  • 10 dBA average noise reduction
  • Conserve compressed air
  • Improved blowoff performance
  • Compact
  • Improved safety
  • Meets OSHA noise level requirements
  • Meets OSHA pressure requirements
  • Improved production

Materials

Zinc Aluminum alloy - general purpose applications. Max temp 250°F (121°C).

Accessories

Stay Set Hose

Stay Set Hose - For applications where frequent repositioning of standard force Air Nozzles or Jet is required, the Flexible Stay Set Hoses™ are ideal. Simply mount the hose in close proximity to the application and bend it to aim the airstream at the target. Since the hose has “memory”, it will not creep or bend. It always keeps the aim until physically moved to the next position.

Swivel Fittings

Swivel Fittings - make it easy to adjust the aim of the Air Nozzles and Jets. Correct placement of the blowing angle can help optimize performance, reduce noise levels and improve efficiency. Swivel Fittings permit a movement of 25 degrees from the center axis for a total movement of 50 degrees. Type 303 or 316 Stainless Steel.

Magnetic Bases

Magnetic Bases - are suited to applications where frequent movement of the Air Nozzle or Jet is required. The powerful magnet permits horizontal or vertical mounting that will hold the blowing position of the Stay Set Hose. A shutoff valve is provided that can be used to vary the force and flow.

Super Air Nozzle Cluster Performance

Air Consumption Force Sound Level
Model SCFM SLPM Lbs Kg dBA
1111-4 56 1,585 3.2 1.45 82
1111-7 98 2,773 5.7 2.59 85
1111-12 168 4,754 9.8 4.45 89

Force measured at 12" (305mm) from target

Sound level measured at 3' (914mm)

All measurements taken at 80 PSIG (5.5 BAR)

How EXAIR Air Nozzles Work

How EXAIR's Air Nozzles Work

Air Nozzles use the Coanda effect to amplify compressed airflow up to 25 times or more. Compressed air is ejected through a series of nozzles on the outer perimeter. As the air travels along the outer wall of the nozzle, surrounding air (blue arrows) is entrained into the stream. The airstream that results is a high volume, high velocity blast of air at minimal consumption. The air is always ejected so it can vent safely, well below OSHA dead end pressure requirements, should the nozzle end be blocked.

Super Air Nozzle Cluster Dimensions & Airflow

EXAIR 1111-4 Super Air Nozzle Cluster
Model 1111-4 Super Air Nozzle Cluster
EXAIR 1111-7 Super Air Nozzle Cluster
Model 1111-7 Super Air Nozzle Cluster
EXAIR 1111-12 Super Air Nozzle Cluster
Model 1111-12 Super Air Nozzle Cluster
To download available CADs and use the 3D viewer, please login and select a model.