Pipe Pressure Drop
The tables in this section provide the air pressure drop in pounds per square inch for a 100 foot length of Schedule 40 Steel Pipe. For lengths other than 100 feet, the pressure drop is proportional to the ratio of difference in lengths.
Example:
For 50 feet of pipe, the pressure drop will be approximately one-half the value given in the table.
For 300 feet of pipe, the pressure drop will be approximately three times the value given in the table.
1/8" Schedule 40 Pipe - 0.269 actual I.D. |
||||||||
Free Air(SCFM) |
Line Pressure (PSIG) |
|||||||
40 |
50 |
60 |
70 |
80 |
90 |
100 |
110 |
|
1 |
1.08 |
0.86 |
0.72 |
0.62 |
0.54 |
0.48 |
0.43 |
0.39 |
2 |
3.88 |
3.10 |
2.59 |
2.22 |
1.94 |
1.72 |
1.55 |
1.41 |
3 |
8.22 |
6.57 |
5.48 |
4.69 |
4.11 |
6.65 |
3.29 |
2.99 |
4 |
- |
- |
9.33 |
7.99 |
6.99 |
6.22 |
5.60 |
5.09 |
5 |
- |
- |
- |
- |
10.57 |
9.39 |
8.45 |
7.69 |
6 |
- |
- |
- |
- |
- |
- |
- |
10.77 |
1/4" Schedule 40 Pipe - 0.364 actual I.D. |
||||||||
Free Air(SCFM) |
Line Pressure (PSIG) |
|||||||
40 |
50 |
60 |
70 |
80 |
90 |
100 |
110 |
|
1 |
0.24 |
0.19 |
0.16 |
0.14 |
0.12 |
0.11 |
0.09 |
0.09 |
2 |
0.86 |
0.68 |
0.57 |
0.49 |
0.43 |
0.38 |
0.34 |
0.31 |
3 |
1.81 |
1.45 |
1.21 |
1.03 |
0.91 |
0.80 |
0.72 |
0.66 |
4 |
3.08 |
2.47 |
2.06 |
1.76 |
1.54 |
1.37 |
1.23 |
1.12 |
5 |
4.66 |
3.73 |
3.11 |
2.66 |
2.33 |
2.07 |
1.86 |
1.69 |
6 |
6.53 |
5.22 |
4.35 |
3.73 |
3.26 |
2.90 |
2.61 |
2.37 |
8 |
- |
8.89 |
7.41 |
6.35 |
5.56 |
4.94 |
4.45 |
4.04 |
10 |
- |
- |
- |
9.60 |
8.40 |
7.47 |
6.72 |
6.11 |
12 |
- |
- |
- |
- |
- |
10.46 |
9.41 |
8.56 |
3/8" Schedule 40 Pipe - 0.493 actual I.D. |
||||||||
Free Air(SCFM) |
Line Pressure (PSIG) |
|||||||
40 |
50 |
60 |
70 |
80 |
90 |
100 |
110 |
|
1 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
2 |
0.19 |
0.15 |
0.13 |
0.11 |
0.09 |
0.08 |
0 |
0 |
3 |
0.40 |
0.32 |
0.26 |
0.23 |
0.20 |
0.18 |
0.14 |
0.14 |
4 |
0.68 |
0.54 |
0.45 |
0.39 |
0.34 |
0.30 |
0.25 |
0.25 |
5 |
1.02 |
0.82 |
0.68 |
0.58 |
0.51 |
0.45 |
0.37 |
0.37 |
6 |
1.43 |
1.15 |
0.96 |
0.82 |
0.72 |
0.64 |
0.52 |
0.52 |
8 |
2.44 |
1.95 |
1.63 |
1.39 |
1.22 |
1.08 |
0.89 |
0.89 |
10 |
3.69 |
2.95 |
2.46 |
2.11 |
1.84 |
1.64 |
1.34 |
1.34 |
15 |
7.81 |
6.24 |
5.20 |
4.46 |
3.90 |
3.47 |
2.84 |
2.84 |
20 |
- |
10.63 |
8.86 |
7.59 |
6.65 |
5.91 |
4.83 |
4.83 |
25 |
- |
- |
- |
- |
10.04 |
8.93 |
7.30 |
7.30 |
30 |
- |
- |
- |
- |
- |
- |
10.23 |
10.23 |
1/2" Schedule 40 Pipe - 0.622 actual I.D. |
||||||||
Free Air(SCFM) |
Line Pressure (PSIG) |
|||||||
40 |
50 |
60 |
70 |
80 |
90 |
100 |
110 |
|
3 |
0.10 |
0.10 |
0.08 |
0 |
0 |
0 |
0 |
0 |
4 |
0.17 |
0.17 |
0.14 |
0.12 |
0.11 |
0.09 |
0.08 |
0.08 |
5 |
0.26 |
0.26 |
0.21 |
0.18 |
0.16 |
0.14 |
0.13 |
0.12 |
6 |
0.36 |
0.36 |
0.30 |
0.26 |
0.22 |
0.20 |
0.18 |
0.16 |
8 |
0.61 |
0.61 |
0.51 |
0.44 |
0.38 |
0.34 |
0.31 |
0.28 |
10 |
0.92 |
0.92 |
0.77 |
0.66 |
0.58 |
0.51 |
0.46 |
0.42 |
15 |
1.95 |
1.95 |
1.63 |
1.40 |
1.22 |
1.09 |
0.98 |
0.89 |
20 |
3.33 |
3.33 |
2.77 |
2.38 |
2.08 |
1.85 |
1.66 |
1.51 |
25 |
5.02 |
5.02 |
4.19 |
3.59 |
3.14 |
2.79 |
2.51 |
2.28 |
30 |
7.04 |
7.04 |
5.87 |
5.03 |
4.40 |
3.91 |
3.52 |
3.20 |
35 |
9.36 |
9.36 |
7.80 |
6.69 |
5.85 |
5.20 |
4.68 |
4.26 |
40 |
- |
- |
9.99 |
8.56 |
7.49 |
6.66 |
5.99 |
5.45 |
45 |
- |
- |
- |
10.55 |
9.32 |
8.28 |
7.45 |
6.78 |
50 |
- |
- |
- |
- |
- |
10.06 |
9.06 |
8.23 |
3/4" Schedule 40 Pipe - 0.824 actual I.D. |
||||||||
Free Air(SCFM) |
Line Pressure (PSIG) |
|||||||
40 |
50 |
60 |
70 |
80 |
90 |
100 |
110 |
|
5 |
0.08 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
6 |
0.11 |
0.09 |
0.07 |
0 |
0 |
0 |
0 |
0 |
8 |
0.19 |
0.15 |
0.12 |
0.11 |
0.09 |
0.08 |
0.07 |
0 |
10 |
0.28 |
0.23 |
0.19 |
0.16 |
0.14 |
0.13 |
0.11 |
0.10 |
15 |
0.60 |
0.48 |
0.40 |
0.34 |
0.30 |
0.27 |
0.24 |
0.22 |
20 |
1.02 |
0.81 |
0.68 |
0.58 |
0.51 |
0.45 |
0.41 |
0.37 |
25 |
1.54 |
1.23 |
1.03 |
0.88 |
0.77 |
0.68 |
0.62 |
0.56 |
30 |
2.16 |
1.73 |
1.44 |
1.23 |
1.08 |
0.96 |
0.86 |
0.78 |
35 |
2.87 |
2.29 |
1.91 |
1.64 |
1.43 |
1.27 |
1.15 |
1.04 |
40 |
3.67 |
2.94 |
2.45 |
2.10 |
1.84 |
1.63 |
1.47 |
1.34 |
45 |
4.57 |
3.65 |
3.04 |
2.61 |
2.28 |
2.03 |
1.83 |
1.66 |
50 |
5.55 |
4.44 |
3.70 |
3.17 |
2.77 |
2.47 |
2.22 |
2.02 |
60 |
7.78 |
6.22 |
5.18 |
4.44 |
3.89 |
3.46 |
3.11 |
2.83 |
70 |
10.34 |
8.27 |
6.89 |
5.91 |
5.17 |
4.60 |
4.14 |
3.76 |
80 |
- |
10.59 |
8.83 |
7.57 |
6.62 |
5.88 |
5.30 |
4.81 |
90 |
- |
- |
10.98 |
9.41 |
8.23 |
7.32 |
6.59 |
5.99 |
100 |
- |
- |
- |
- |
10.00 |
8.89 |
8.00 |
7.27 |
125 |
- |
- |
- |
- |
- |
- |
- |
10.99 |
1" Schedule 40 Pipe - 1.049 actual I.D. |
||||||||
Free Air(SCFM) |
Line Pressure (PSIG) |
|||||||
40 |
50 |
60 |
70 |
80 |
90 |
100 |
110 |
|
50 |
1.66 |
1.33 |
1.11 |
0.95 |
0.83 |
0.75 |
0.66 |
0.60 |
60 |
2.33 |
1.86 |
1.55 |
1.33 |
1.16 |
1.03 |
0.93 |
0.85 |
70 |
3.09 |
2.47 |
2.06 |
1.77 |
1.55 |
1.37 |
1.24 |
1.12 |
80 |
3.96 |
3.17 |
2.64 |
2.26 |
1.98 |
1.76 |
1.58 |
1.44 |
90 |
4.92 |
3.94 |
3.28 |
2.81 |
2.46 |
2.19 |
1.97 |
1.79 |
100 |
5.98 |
4.79 |
3.99 |
3.42 |
2.99 |
2.66 |
2.39 |
2.18 |
125 |
9.04 |
7.23 |
6.03 |
5.17 |
4.52 |
4.02 |
3.62 |
3.29 |
150 |
- |
10.13 |
8.44 |
7.24 |
6.33 |
5.63 |
5.07 |
4.61 |
175 |
- |
- |
- |
9.63 |
8.42 |
7.49 |
6.74 |
6.13 |
200 |
- |
- |
- |
- |
10.78 |
9.59 |
8.63 |
7.84 |
225 |
- |
- |
- |
- |
- |
- |
10.73 |
9.75 |
1.25" Schedule 40 Pipe - 1.380 actual I.D. |
||||||||
Free Air(SCFM) |
Line Pressure (PSIG) |
|||||||
40 |
50 |
60 |
70 |
80 |
90 |
100 |
110 |
|
50 |
0.42 |
0.34 |
0.28 |
0.24 |
0.21 |
0.19 |
0.17 |
0.15 |
60 |
0.59 |
0.47 |
0.39 |
0.34 |
0.30 |
0.26 |
0.24 |
0.21 |
70 |
0.78 |
0.63 |
0.52 |
0.45 |
0.39 |
0.35 |
0.31 |
0.29 |
80 |
1.00 |
0.80 |
0.67 |
0.57 |
0.50 |
0.45 |
0.40 |
0.37 |
90 |
1.25 |
1.00 |
0.83 |
0.71 |
0.62 |
0.56 |
0.50 |
0.45 |
100 |
1.52 |
1.21 |
1.01 |
0.87 |
0.76 |
0.97 |
0.61 |
0.55 |
125 |
2.29 |
1.84 |
1.53 |
1.31 |
1.15 |
1.02 |
0.92 |
0.83 |
150 |
3.22 |
2.57 |
2.14 |
1.84 |
1.61 |
1.43 |
1.29 |
1.17 |
175 |
4.28 |
3.42 |
2.85 |
2.44 |
2.14 |
1.90 |
1.71 |
1.55 |
200 |
5.47 |
4.38 |
3.65 |
3.13 |
2.74 |
2.43 |
2.19 |
1.99 |
225 |
6.81 |
5.45 |
4.54 |
3.89 |
3.40 |
3.03 |
2.72 |
2.48 |
275 |
9.87 |
7.89 |
6.58 |
5.64 |
4.93 |
4.39 |
3.95 |
3.59 |
300 |
- |
9.27 |
7.73 |
6.62 |
5.80 |
5.15 |
4.64 |
4.21 |
325 |
- |
10.75 |
8.96 |
7.68 |
6.72 |
5.97 |
5.38 |
4.89 |
350 |
- |
- |
10.28 |
8.81 |
7.71 |
6.85 |
6.17 |
5.61 |
375 |
- |
- |
- |
10.01 |
8.76 |
7.78 |
7.01 |
6.37 |
400 |
- |
- |
- |
- |
9.87 |
8.77 |
7.89 |
7.18 |
450 |
- |
- |
- |
- |
- |
10.91 |
9.82 |
8.92 |
500 |
- |
- |
- |
- |
- |
- |
- |
10.84 |
1.5" Schedule 40 Pipe - 1.610 actual I.D. |
||||||||
Free Air(SCFM) |
Line Pressure (PSIG) |
|||||||
40 |
50 |
60 |
70 |
80 |
90 |
100 |
110 |
|
50 |
0.19 |
0.16 |
0.13 |
0.11 |
0.10 |
0.09 |
0.08 |
0 |
60 |
0.27 |
0.22 |
0.18 |
0.16 |
0.14 |
0.12 |
0.11 |
0.10 |
70 |
0.36 |
0.29 |
0.24 |
0.21 |
0.18 |
0.16 |
0.15 |
0.13 |
80 |
0.46 |
0.37 |
0.31 |
0.27 |
0.23 |
0.21 |
0.19 |
0.17 |
90 |
0.58 |
0.46 |
0.39 |
0.33 |
0.29 |
0.26 |
0.23 |
0.21 |
100 |
0.70 |
0.56 |
0.47 |
0.40 |
0.35 |
0.31 |
0.28 |
0.26 |
125 |
1.06 |
0.85 |
0.71 |
0.61 |
0.53 |
0.47 |
0.42 |
0.39 |
150 |
1.49 |
1.19 |
0.99 |
0.85 |
0.74 |
0.66 |
0.60 |
0.54 |
175 |
1.98 |
1.58 |
1.32 |
1.13 |
0.99 |
0.88 |
0.79 |
0.72 |
200 |
2.53 |
2.03 |
1.69 |
1.45 |
1.27 |
1.13 |
1.01 |
0.92 |
225 |
3.15 |
2.52 |
2.10 |
1.80 |
1.57 |
1.40 |
1.26 |
1.15 |
275 |
4.57 |
3.65 |
3.04 |
2.61 |
2.28 |
2.03 |
1.83 |
1.66 |
300 |
5.36 |
4.29 |
3.58 |
3.06 |
2.68 |
2.38 |
2.15 |
1.95 |
325 |
6.22 |
4.97 |
4.15 |
3.55 |
3.11 |
2.76 |
2.49 |
2.26 |
350 |
7.13 |
5.71 |
4.75 |
4.08 |
3.57 |
3.17 |
2.85 |
2.59 |
375 |
8.10 |
6.48 |
5.40 |
4.63 |
4.05 |
3.60 |
3.24 |
2.95 |
400 |
9.13 |
7.30 |
6.09 |
5.22 |
4.57 |
4.06 |
3.65 |
3.32 |
450 |
- |
9.08 |
7.57 |
6.49 |
5.68 |
5.05 |
4.54 |
4.13 |
500 |
- |
- |
9.20 |
7.88 |
6.90 |
6.13 |
5.52 |
5.02 |
550 |
- |
- |
10.97 |
9.40 |
8.23 |
7.31 |
6.58 |
5.98 |