Hot Tap Digital Flowmeter™
EXAIR’s Hot Tap Digital Flowmeter™ allows for installation under pressure, eliminating the need to isolate and remove pressure from
Only %1 left
EXAIR’s Hot Tap Digital Flowmeter™ allows for installation under pressure, eliminating the need to isolate and remove pressure from the pipe it is being installed upon. It incorporates two valves that the probes pass through and a muffler that collects chips from the drilling process. It takes an equally short amount of installation time as the standard meters. Available on 2" through 8" flowmeters. The digital display shows the exact amount of compressed air being used, making it easy to identify costly leaks or inefficient air products. No cutting, welding, adjustments or calibration are ever required. Hot Tap Digital Flowmeters are not a stock item and ship in three to five days. Consult the factory for NEMA 4 flowmeters.
Advantages
- Easy to install - No moving parts
- Summing Remote Display and Data Logger available
- Optional RS-485 output serial communication board available
- Sensitive at low flows
- No calibration or setup required
- Includes all components for installation
- Models are available for sizes 2" to 8" in iron pipe
- Models are available for sizes 2" to 6" in copper pipe
Digital Flowmeter Models
- Models are available for 2" through 8" Schedule 40 iron pipe.
- Models are available for 2" through 6" copper pipe.
- Metric or English unit displays can be specified for all model sizes.
Accessories
USB Data Logger
EXAIR's award-winning USB Data Logger Model 9147 connects directly to the Digital Flowmeter and is simple to use. It can be configured to record flow rate from once per second to once every 12 hours. Data can be read with included software or imported into a spreadsheet.
Summing Remote Display
The Summing Remote Display allows remote viewing of Digital Flowmeter data. Additional features include: current air consumption, usage for the previous 24 hours, and total cumulative usage.
Block-Off Ring
The Block-Off Ring is necessary should you decide to remove or relocate your Digital Flowmeter.
Specifications - Digital Flowmeter | |
Accuracy | 5% of reading plus 1% of range for flows from 10% to 100% of indicated range at air temperatures between 20° to 120°F. |
Operating Pressure | 130 PSIG maximum on Sch. 40 iron. Consult EXAIR for other materials and at higher pressures. |
Input Power | 250 mA at 24 VDC |
Output Resistance | 600 Ohms maximum |
Wetted Materials | Stainless steel, gold, thermal epoxy, Viton, PTFE, Aluminum |
Ring Material | Aluminum |
Display | Four-digit LED display |
Response Time | One second to 63% of change in value at flows above 30% of range. |
Pressure Range | N/A |
Compliance | CE and RoHS |
Note: For use with compressed air and nitrogen only. |
Dimensions and Flow Range - Hot Tap Digital Flowmeter - Schedule 40 Pipe |
||||
A |
||||
Model | Pipe Size |
in | mm | Flow Range |
H9095 | 2" | 6.43 | 163 | 6-600 SCFM (10.2-1020 m3/hr) |
H9096 | 2-1/2" | 7.20 | 183 | 8-800 SCFM (13.6-1359 m3/hr) |
H9097 | 3" | 7.82 | 199 | 12-1200 SCFM |
H9098 | 4" | 8.82 | 224 | 20-2000 SCFM |
H90100 | 6" | 10.95 | 278 | 50-5000 SCFM |
H90101 | 8" | 12.95 | 329 | 100-6000 SCFM |
Dimensions and Flow Range - Hot Tap Digital Flowmeter - Copper Pipe |
||||
A |
||||
Model | Pipe Size |
in | mm | Flow Range |
H9095CU | 2" | 6.18 | 157 | 6-600 SCFM (10.2-1020 m3/hr) |
H9096CU | 2-1/2" | 6.95 | 177 | 8-800 SCFM (13.6-1359 m3/hr) |
H9097CU | 3" | 7.45 | 189 | 10-1000 SCFM (17-1699 m3/hr) |
H9098CU | 4" | 8.45 | 215 | 20-2000 SCFM (34-3398 m3/hr) |
H90100CU | 6" | 10.45 | 265 | 40-4000 SCFM (68-6796 m3/hr) |